NFPA 211, read one item at a time
Get a code repair quote
Tell us which items the inspection listed and how many fireplaces or units they cover.
Item one: clearance to combustibles
The code wants an air space between a masonry chimney and the wood around it, and limits how close a mantel, trim or framing can sit to the firebox opening. On older houses and on condo buildings with wood-framed chases, this is often where an inspection stops. The camera sees framing or debris touching the outside of the flue, or a mantel added during a remodel sits too low.
The repair depends on what is touching what. Trim can be cut back or a mantel raised. Framing against the masonry inside a wall means opening the wall. Each of these is quoted in writing after we see it, unit by unit, because no two walls are built alike.
Item two: a liner that is whole and sized right
A flue must carry smoke and gas from the appliance to the top without leaks into the house or the framing. Cracked clay tiles, missing mortar between tiles, or a liner too large or too small for a new insert all fail this item. In multi-unit buildings, one stack often holds several flues side by side, so a crack can let one unit's exhaust reach another.
Relining is the usual answer: a stainless liner run inside the old flue and sized to the appliance. It is quoted in writing per flue. When the liner is being installed for a gas insert, the insert itself has a printed price below.
Item three: the top of the chimney
Caps, spark screens and the masonry or metal at the top are where most California chimneys show their age first. A missing cap lets rain and animals in. A spark screen that has rusted through lets embers out, and fire authorities in brush and wind areas look for one on a wood-burning chimney. Water that gets past the top shows up later as a leak inside.
Leaks traced from the roof line have a printed range. Where water collects behind a wide chimney on the uphill side of a roof, a cricket diverts it, and it has its own price, with or without new flashing. A new cap is quoted after we measure.
- Leak tracing and repair: printed range
- Cricket, alone or with new flashing: printed range
- Crown, chase cover, damper, flashing alone: written quote
- Cap with spark screen: quoted after we measure
Item four: the appliance and its venting
A gas insert or a vented gas fireplace has to match its listing: the right vent, the right termination, the right gap to anything that burns. Older units in condo buildings sometimes run on venting that was never approved for them.
Where the right answer is a new gas insert in the existing opening, that has a printed range. A fresh camera inspection after the work confirms the item is closed and goes into the file.
Printed prices for common code fixes
These are the repairs we can price before we arrive. Each is per chimney or per fireplace.
- Water entry traced and stopped
- $525 to $3,150
- Roof diverter behind the stack
- $420 to $950
- Diverter plus all new step and counter flashing
- $630 to $1,600
- Sealed gas unit set into your firebox
- $2,650 to $5,250
- Follow-up camera run to close the item
- $370
- New top cap with ember screen
- Quoted after we measure
Anything else, such as a crown, a liner, a damper, a chase cover or flashing by itself, gets a written quote once we have looked at it.
Code repair questions
Which code is my chimney held to?
Inspections follow NFPA 211. Construction rules for masonry fireplaces and chimneys are in the California Residential Code, and your city may add its own requirements on top.
Does an old chimney have to meet today's code?
Not every line of it. The items that matter are the ones about safe venting and clearance, and those apply to a chimney in use whatever its age.
Can you fix only the items on someone else's report?
Yes. Tell us what the report lists. We confirm each item on site before we quote it, so the figure matches what is actually there.
Why are some repairs not priced on this page?
Crowns, liners, dampers, chase covers and flashing vary too much from building to building to print. Each is quoted in writing after we see it.
How do I show the item is fixed?
After the repair we can run the camera again and issue a dated record that the item is closed, which goes to whoever booked the work.
Bring the list, get each item priced
Tell us what the inspection flagged and how many fireplaces it covers, and we will quote each item in writing.
Call (562) 449-0453